Learn how to calibrate, maintain and inspect a Peel/Seal/Bond Strength Tester for reliable flexible packaging quality control. Covers force verification, grips, test speed, ASTM F88 and ASTM D3330, common errors, preventive maintenance and MARK testing machine configurations.
A Peel/Seal/Bond Strength Tester is an important quality-control instrument for manufacturers of flexible packaging, laminated films, adhesive tapes, labels and heat-sealed packaging materials.
Reliable test results depend not only on machine accuracy but also on correct specimen preparation, suitable grips, testing speed, calibration and preventive maintenance.
An incorrectly maintained testing machine can produce inconsistent force readings, specimen slippage, inaccurate peel results and unreliable quality-control records.
MARK Testing Instruments offers Digital, Computerized and HMI configurations of Peel/Seal/Bond/Adhesion Strength Testers for flexible packaging and industrial laboratories.
This guide explains the calibration checks, maintenance procedures and testing practices that help laboratories maintain reliable results.
A Peel/Seal/Bond Strength Tester is a force-measuring instrument used to evaluate the resistance of suitable materials to separation under controlled loading conditions.
Depending on the fixture and method, it can perform:
The machine applies controlled movement while measuring the force required to separate the specimen.
The results help manufacturers evaluate packaging seal integrity, adhesive performance and material consistency.
Calibration helps establish the relationship between the instrument's measured values and recognized reference values.
For Peel/Seal/Bond Strength Testers, force measurement is particularly important because test results are often reported as force or force per unit specimen width.
Calibration and verification help laboratories:
Calibration should cover the actual measurement range used by the laboratory.
A machine with a high maximum capacity is not automatically suitable for very low-force testing.
Force measurement is the primary parameter.
Check:
Use suitable calibrated reference equipment and an approved procedure.
Peel and seal strength results can depend on the rate of separation.
The testing speed should be verified against the selected test method.
Where displacement or extension is reported, verify the measurement system as required by the laboratory procedure.
Grips should be inspected for wear, damage and improper alignment.
Fixture condition is an important functional check, although it is not a substitute for instrument calibration.
For Computerized and HMI systems, verify:
ASTM F88/F88M addresses seal strength testing of flexible barrier materials.
The procedure and specimen configuration must follow the selected method.
ASTM D3330/D3330M addresses peel adhesion of pressure-sensitive tape.
The selected procedure must be appropriate for the tape and substrate.
Seal strength and adhesive peel strength are not identical properties.
The same testing frame may support both applications, but specimen preparation, grips, peel geometry and result interpretation can differ.
Before calibration, inspect:
Do not use equipment with visible mechanical or electrical damage.
Ensure the force measurement system is unloaded and follow the manufacturer's zeroing procedure.
Apply appropriate reference forces using a suitable calibrated system.
Compare the indicated force with the reference values.
Repeat measurements at selected points according to the approved verification procedure.
Check the actual crosshead movement rate against the required speed.
Confirm that grips and fixtures are installed correctly and do not introduce unintended loading.
Where applicable, verify that displayed values, calculations and reports are consistent with the measured data.
Record:
If a parameter falls outside the specified limits, stop relying on the affected measurement function until the issue has been investigated and corrected.
Resume routine testing only after the instrument meets the laboratory's acceptance requirements.
Before starting testing:
Periodic maintenance should follow the manufacturer's instructions.
Activities may include:
Maintenance frequency should reflect machine usage, environmental conditions and laboratory quality requirements.
Possible causes
Corrective actions
Possible causes
Corrective actions
Possible causes
Corrective actions
Possible causes
Corrective actions
Possible causes
Corrective actions
Suitable for routine peel, seal and bond force measurement.
Selected specifications include:
Provides digital force measurement with printed result documentation on the configured model.
Designed for software-based test control and reporting.
Depending on configuration, features can include:
Designed for standalone touchscreen operation with test settings and result management.
Combines touchscreen operation with computer-based functionality on the specified configuration.
| Parameter | Specification |
|---|---|
| Instrument | Peel/Seal/Bond/Adhesion Strength Tester |
| Brand | MARK Testing Instruments |
| Standard Digital Load Cells | 3 kgf / 10 kgf |
| Digital Readability | 0.001 kg |
| Stated Digital Accuracy | ±0.05% |
| Speed | Variable, model dependent |
| Test Geometry | According to fixture and method |
| Peak Hold | Available on Digital model |
| Printer | Selected configurations |
| Computer Software | Selected configurations |
| HMI | Selected configurations |
| Warranty | 12 Months |
Final specifications and the basis of the stated accuracy should be confirmed in the model quotation.
There is no universal calibration interval suitable for every machine.
The laboratory should determine the interval based on:
An annual calibration interval is commonly considered by laboratories, but the actual schedule should be justified by the laboratory's requirements.
Equipment and maintenance costs depend on:
A suitable machine should be evaluated on both purchase price and long-term measurement reliability.
Calibration evaluates measurement performance against reference values. Maintenance involves inspecting and servicing the equipment to keep it functioning correctly.
ASTM F88/F88M is a relevant method for seal strength of flexible barrier materials.
ASTM D3330/D3330M is relevant to peel adhesion of pressure-sensitive tape.
Yes, a suitably configured testing machine can support multiple methods using the appropriate grips, fixtures and test settings.
Yes. MARK offers Computerized Peel/Seal/Bond Strength Tester configurations.
Yes. MARK offers HMI configurations with features dependent on the selected model.
MARK Testing Instruments offers Digital, Printer, Computerized and HMI configurations for flexible packaging and adhesive testing laboratories.
For technical selection, provide:
Material + Test Standard + Expected Force + Specimen Width + Peel Geometry + Reporting Requirements